Bowie and Dick Test Disinfector with USB Reader Box/Practical Steam Steriliser Facility for Clinic
1- Main Feature
(a)The vacuum data can reach -0.8bar, it fits various instrument, including package,unpackaged,solid,hollow,multi-apertures and inset pipes.
(b) It makes sure the instrument can be sterilized completely.
(c) Fuzzily computer controlled, digital bright show. The interface is modularized panel for easy operation.
(d) It is installed with BOWIE&DICK which measures the penetration of water steam.
*Electronic Control microprocessor
*Programs 8
*Test method 3
*Cycle recording Yes
*Steel chamber AISI 304
*Temperature sensors in chamber1
*Vacuum pump Dual head
*Water pump 1 ULKA water pump
*Tank sensor 2,used water sensor & distilled water sensor
*Safety feature Electric-Mechanical dual interlock, Mechanical safety valve, alarms when door opened, Water level control, over heating control, over pressure protection, error messages viewed on the display
*Alarm indications 10
*Conformity 93/42/EEC, EN 13060, EN 61010
Autoclavable accessries
Basic basket and support- for surgical instruments used in the operating room.
3-Daily Maintenance
Cleaning Door Gasket
The door gasket and the mating surface should be wiped off clean each day with a clean, damp cloth. Do not use abrasive cleaners on the gasket or mating surface.
Use warm soapy water for keeping marks of sterilizer persistent, but ensure any soap residues are completely removed by wiping both the gasket and the vessel again with water using a lint free damp cloth.
WARNING | Refer to qualified personnel for servicing: Never use a wire brush, steel wool, abrasive material, or chloride-containing products to clean door and chamber assembly. "Caution hot surface. Avoid contact." ensure that the sterilizer is cooled down fully before cleaning to avoid burns. |
Cleaning After Liquid Loads
Biological media tends to boil at a higher rate than other liquids during venting. This causes media to be spattered inside the chamber. Therefore, the chamber must be cleaned daily when you are sterilizing media. Cleaning as follows:
* Allow unit to be cooled down.
* Wipe out chamber and door with a clean, damp cloth.
WARNING | Failure to keep the interior of the stainless steel chamber free of mineral deposits and debris can cause premature failure of the sterilizer. |
4- Packing details
Item Nr. | Power | Chamber size | Unit size | Packing size | Weight |
Novo B+ 18 | 1500w | 18L=245X360mm | 560X450X400mm | | 47kgs |
5- Payment details
T/T, L/C & west union acceptable.
6- Shipment
Express: 1 or 2pcs samples testing, express recommended.e.g: TNT,DHL,UPS etc. Shipping days 3-5days.
Air shipment: Between 3pcs and 5pcs, normal air shipment recommended. Shipping days 5-10days.
Sea shipment: More than 6pcs, normal sea shipment recommended. Shipping days around 30days.