Table Sterilizers Using Water Distilled/Distilled Water Apparatus Machine
1) 4L capacity
2) 1/H water flow
3) 4 Hours full capacity
4) Stainless steel chamber and top
5) Visible carbon capsule, easy to replace.
Specification
Essential Parameter RatedVolyage: a.c.220V-240V,50/60Hz RatedPower: 750VA Fuse:250vT10A OperatingTemperature: 5~40℃ Noise:<50db Speed:1.2L/H WaterRate:≥96% | Chamber Material:Stainless Steel304 MaxiumCapacity:4L TheHighest Temperature: 120 ℃ VolumeCavity Size:φ180*185 |
Temperature Safety Protection: Cavitytemperature protection:115 ℃ Temperatureof the heating element protection:170 ℃ |
Setting
Open the packing chest. Take the distiller out of the chest. Then take the storage bucket out of the distiller. Set the distiller on a stable surface in terms of picture 1.
Open the cover (As picture 2). Pour proper volume of water into the chamber within the highest waterline. (Remark:As the cover connects tightly with the body, please press the body with one hand, and pull the cover upward with another.)
ATTENTION | As the cover connects tightly withthe body, please hold the body with one hand, and pull the cover upward withanother. |
Set the storage bucket stably according to picture 1, insert the one end of power cord into the body, and another into correct electric outlet.
Starting
Open the power switch (If the power switch off, press the heating button), If the indicator light in power switch on, it means start to heating. After a period of time, the cooling fan will run automatically for distilling.
It takes about 3.5 hours to distill 4L water, and the first pure drop will appear after half an hour, according to local temperature.
WARNING | FOR AVOIDING BEING SCALDED, DO NOTOPEN THE COVER WHILE WORKING. |
Ending
When distilling finished, the heating system will stop automatically, and indicator light will be off. However, the cooling fan will keep running until the chamber temperature drops below 70 degree C.
CAUTION | Heating button is incharge of heating process start. The heating process will stop automaticallywhen there is no water or no water for distilling. (When heating, indicatorlight in power switch on; stopping, off). Power switch controls both ofheating and cooling fan's running. |
CAUTION | For filtering, the distilleris furnished with active carbon. In accordance with demand, you can put theactive carbon into the faucet, and cover with filter cap. Remark: replace theactive carbon regularly. |
CAUTION | As upper cover is heavy,do not open and erect it while using. |
Power Off
Please Close the power switch when no longer in use.
Please pull the end of power cord out of electric outlet when no longer in use of distiller.
Packing details
26*26*42 cm (1pc)
60*52*48 cm (4pcs)
Payment details
T/T, L/C & west union acceptable.
Shipment
Express: Under 10pcs samples testing, express recommended.e.g: TNT,DHL,UPS etc. Shipping days 3-5days.
Air shipment: Between 10pcs and 20pcs, Normal air shipment recommended. Shipping days 5-10days.
Sea shipment: More than 20pcs, Nor sea shipment recommended. Shipping days around 30days.